My new boot Total Station RTS620 displayed after turning the lens
Turn the camera power after the top of the screen shows how to deal with Tilt Over, younger brother first time the total station. Were previously in the unit to the Survey. Enlighten you to the master
Turn the camera power after the top of the screen shows how to deal with Tilt Over, younger brother first time the total station. Were previously in the unit to the Survey.
Enlighten you to the master
Compensation is not overrun ah? Leveling instruments need to take another look.
Should now have an absolute encoder dial, right? Or just need to have zero vertical angle.
That is, turn the telescope around.
The first try.
Not too well on this instrument.
Buy a new instrument to compensation out of the way Yeah, I think unlikely, is not your brother are not the whole apparatus to turn the zero level
602 SYG high accuracy, it should be no leveling.
How to diy the prism
Yesterday, half the measured cross section measurements, rain, umbrella test completely Department, back before I found the prism inside the mirror all the three small drops of water.
To open to rub, but I do not know how demolition, tearing down I do not know can not hold back, even if the equipment back, will not be affected. Is it scrapped under the prism of this?
Not actually tested, but should be able to water with mechanical precision machinery similar approach can be used most of the following methods
Posted the following mechanical approach:
A watch with a piece of cloth to wrap and then into the lime inside, the next day just fine
2 available granular material called silicone and has a watch with water into a sealed container for several hours, remove the watch, water is all gone. This method is simple, economic, and life on the accuracy of the table not have any damage. Silica gel after absorbing water many times, dried at 120 ℃ for several hours, water absorption capacity can be recycled, but also repeated use.
3 If the water is not serious, just a layer of fog inside the glass table, then can easily absorb moisture layers of toilet paper or flannel will form package Yan, 40-watt light bulb at a distance of 15 cm at the bake about 30 minutes, then remove the water gas. Should not mask the table near the fire heated directly, so as not to suffer thermal deformation of the table. Mongolia and DPRK can also form within the bottom shell outwards, anti-worn on the wrist, two hours after the water vapor can be removed. If the water seriously, the best shops Cayou immediately sent to the table, clear the movement of water, spare parts to avoid rust.
If the prism of water, and you just unscrew the protective cap, rub a bit on it, you can continue to use.
If water is your total station shot, and I suggest you to professional service agencies
Somehow, the edges of the mirror from the top of a crack with a toothpick, and then blowing hair dryer, dry quickly, and have affected the accuracy of estimates. Anyway, do not be so dam accurate, with the first of the. The vigorously shaking the prism can now hear sound.
First came across such a failure! ! !
Customer response to the problem called to him to the whole anxious, but also the whole confused, and did a few years he is also the first time measure to meet such problems. Customers from the company bought a Pentax 202N, is a project of a new highway department captain of measurement. Early retest adjustment results when the wire is a pass. As before are used to measure distance and angle. Coordinate the past few days found that in addition to the problem, the failure is as follows: A and B are known to two known points, the distance between two points about 130 meters away from the directly measured level distance between two points is accurate, no problem. With a coordinate measurement on a problem. A test site stand point, rear point B, X axis and the deviation of 1.6 cm design, Y-axis no problem. Pressure flip key to display the distance and angle of the interface that is also a short distance of 1.6 cm, and then exit the coordinate measuring interface, the interface directly in the initial ranging, this time the distance measured is accurate, no problem. . . . .
The customer's own routine examination of the instrument: on in the bubble tube is no problem, 2C, I angle has been controlled in 2 seconds. Accessories such as wooden stand on the bar + bracket, prism, etc. no problem. Customers very carefully, there are other two instruments site is Forleda and Su light, these two points were observed, the measured data and design values are the same. When the instrument is not a curse customer calls can not, but get the facts speak, high-quality, in this struggle to other surveyors in the measurement line to pay tribute.
Eliminate these problems only software failure or hardware failure, allowing customers access to the internal procedures according to instructions, did not find problems, not in a hurry to restore the factory settings, which ultimately set the coordinate system in the seventh options that do not know who to modify the elevation factor into 750, and the factory setting is 0. After the change over all normal. Write so much, as if the whole lot of trouble, in fact, like the instrument to restore the factory settings, but the instrument instrument to restore the factory settings is not very useful, still have to manually change some settings in order to achieve the best effect measurements.
Total station (theodolite) Graphic Card axis
Accidentally found this site really is good, since it is first posted I hope to have made more sense, here is the problem of Total Station graphic card axis, in the hope that we can help.
1. Vertical axis scratch, you can see from the arrows of a visible scratches, which is card-axis was the reason why, generally due to the shaft and sleeve or between the impurities into the shaft (sleeve) on itself, a small burr have caused. This relatively deep scratches in the picture, so have a vertical axis generally repaired only degraded to use.
2. This is the picture sleeve was scratched because of camera white balance when there is no fine, looks blue too, we make do see it.
So, if we have the process in the use of total station instrument cards shaft suddenly found, please do not try and turn the instrument body, sent to repair office equipment repair, new equipment had to contact your dealer if replacement or repair, or Scratch the above was the same as the original deeper, making it difficult to repair or not repair was the consequences of the original accuracy.
This is my bit of experience too, hope that more exchanges ~
Nikon 350 Total Station 60 meters without signal
I have a Nikon 350 units in total station is now a problem with symptoms ranging no signal outside the 60 meters, 60 meters of another signal, may I ask the older generation this is why??
This phenomenon, there are two possibilities:
The first position is called drift, as is the distance and the collimation axis deviation, you can try to cross-wire side to the left and right or up and down some, may be measured back.
Second, the light intensity attenuation is a common problem Nikon Total Station! Common in use more than 2 years, that the above test methods are still not ranging.
For repair it! Cost:
1, ¥ 800 ~ 2000 (maintenance department in your area to see the black is not black, huh, huh);
2, ¥ 5000 ~ 8000 (see your negotiating skills a).
Price is not down to look about us Well, hey
Axis is to look at your side is how a partial law, and it depends on the transmitter side is the side or the receiving end, the cross-wire transmitter to correct only the upper and lower error correction and change even after the index finished worse! If the partial method, on the other a little trouble! To disassemble it!
Nikon 350 Total Station is a common long side without signal failure. Axis is not parallel to the small problem! ! ! ! ! ! 15 minutes to resolve.
Only one test-bed that no other repair tool how to troubleshoot? The hands of just such a situation there is one.
I have a table Nikon 530E, triaxial good, firing the laser spot Ye Hao, that is, do not know whether to accept a problem, or other problems